UM Series Nano Spectrophotometer

A nano-volume spectrophotometer with full UV-Vis wavelength scanning from 200-900 nm, built for samples where only microlitres are available.

Category Nano Spectrophotometer In production
UM Series Nano Spectrophotometer core specifications
Wavelength Range 200-900nm
Optical Path 1mm

Send your sample type and method, and we will confirm the configuration and current lead time.

Ask about this model

[email protected]

Model comparison

UM Series Nano Spectrophotometer range at a glance

Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.

UM Series Nano Spectrophotometer — 6 models
ParameterUM-100UM-110UM-200UM-220UM-300UM-330
Optical Path1mm1mm1mm/0.5mm/0.05mm (Manual)1mm/0.5mm/0.05mm (Auto)1mm/0.4mm/0.1mm/0.04mm/0.02mm (Auto)1mm/0.4mm/0.1mm/0.04mm/0.02mm (Auto)
Detector1024 (CMOS) linear image sensor2048 (CMOS) linear image sensor2048 (CMOS) linear image sensor2048 (CMOS) linear image sensor4096 (CMOS) linear image sensor4096 (CMOS) linear image sensor
Wavelength Range200-900nm200-900nm200-900nm200-900nm200-900nm200-900nm
Wavelength Accuracy±2.0nm±1.0nm±1.0nm±1.0nm±1.0nm±1.0nm
Wavelength Repeatability±1.0nm±0.5nm±0.5nm±0.5nm±0.5nm±0.5nm
Absorbance Range——Ultra-micro Mode: 0-600Abs (@10mm), Cuvette Mode: 0-3Abs (@10mm)Ultra-micro Mode: 0-600Abs (@10mm), Cuvette Mode: 0-3Abs (@10mm)Ultra-micro Mode: 0-600Abs (@10mm), Cuvette Mode: 0-3Abs (@10mm)Ultra-micro Mode: 0-600Abs (@10mm), Cuvette Mode: 0-3Abs (@10mm)
Nucleic acid measurement range2-750ng/μl2-750ng/μl2-15000ng/μl (dsDNA)2-15000ng/μl (dsDNA)1-37500ng/μl (dsDNA)1-37500ng/μl (dsDNA)
Protein measurement range1-15mg/mL1-15mg/mL1-400mg/mL (BSA)1-400mg/mL (BSA)1-1120mg/mL (BSA)1-1120mg/mL (BSA)
Nucleic acid detection module——dsDNA, ssDNA, RNA, User-Setting, oligoDNA, oligoRNA, and Gene Chip ModuledsDNA, ssDNA, RNA, User-Setting, oligoDNA, oligoRNA, and Gene Chip ModuledsDNA, ssDNA, RNA, User-Setting, oligoDNA, oligoRNA, and Gene Chip ModuledsDNA, ssDNA, RNA, User-Setting, oligoDNA, oligoRNA, and Gene Chip Module
Protein detection module——A280, Polypeptide, Protein Chip, BCA, Bradford, Lowry, and Pierce 660 ModuleA280, Polypeptide, Protein Chip, BCA, Bradford, Lowry, and Pierce 660 ModuleA280, Polypeptide, Protein Chip, BCA, Bradford, Lowry, and Pierce 660 ModuleA280, Polypeptide, Protein Chip, BCA, Bradford, Lowry, and Pierce 660 Module
OD600 Module——Cell fluid testing moduleCell fluid testing moduleCell fluid testing moduleCell fluid testing module
Cuvette Wavelength Range—200-900nm—200-900nm—200-900nm
Cuvette Specifications—1mm/2mm/5mm/10mm—1mm/2mm/5mm/10mm—1mm/2mm/5mm/10mm
Cuvette Type—Micro reusable cuvette—Micro reusable cuvette—Micro reusable cuvette

Overview

What this instrument measures, and how it fits the range.

The UM Series Nano Spectrophotometer covers six models, UM-100 to UM-330, with wavelength accuracy from ±1 nm to ±2 nm and a 1 mm optical path across the range. The two sub-families are built for different workflows, so their features are listed separately.

UM-100 and UM-110

  • Minimal sample volume required, with full UV-Vis wavelength scanning.
  • No preheating required, so the instrument is ready to test at any time.
  • Fast detection speed, with the concentration value displayed directly.
  • Samples do not need to be diluted, and the data statistics software is easy to master.

UM-200, UM-220, UM-300 and UM-330

  • A built-in optical fiber prevents breakage from external impact, which would otherwise lead to inaccurate results.
  • Multiple data output ports allow test data to be exported freely.
  • The software supports remote operation.
  • Standard curves support several fitting functions: linear, interpolation, second-order polynomial and third-order polynomial.
  • Optional modules include full-wavelength scanning, standard curve quantitative analysis, kinetics and photometric measurement.

Key points

  • Touchscreen pad interface with multi-interface design and automatic Bluetooth connection. Real-time data monitoring and automatic performance optimization. Software-aided fault inspection and localization.
  • Multi-color status indicators: blue for ongoing self-test, yellow for standby or preheating, green for normal operation and red for faults such as an abnormal light source.
  • One-click switching between microvolume mode and cuvette mode without additional disassembly, covering analysis from microvolume to regular samples on one instrument.
  • Pre-set program calling supports one-click startup and preloading of frequently used programs, shortening test startup time.
  • Long-life xenon lamp paired with a high-pixel linear CMOS sensor, covering 200-900 nm with absorbance from 0 to 600 Abs. A single measurement completes within 5 seconds.
  • Quantum-level sensitive materials in the light-detecting components capture photons and resolve subtle changes in light passing through the sample.
  • Real-time SMS and email push when the instrument fails or a result is abnormal, with errors, warnings and informational messages recorded as they occur.
  • Operating software carries 21 CFR functions, with system administrator, administrator and operator roles separated by distinct permissions.
  • Cloud interconnection: the IoT platform supports real-time monitoring and remote control, with data upload, storage, viewing and sharing across WeChat Mini Program, APP and desktop.

Full specifications for this model are listed at the top of this page.

Accessories

Confirm these items before the final quotation. Accessories are listed only where the manufacturer offers them.

Standard accessories

Ask for an itemized quotation that separates standard items from options.

Optional accessories

No optional accessories are published for this model. Confirm availability with our team.

Specifications can depend on the selected configuration. Confirm the current datasheet, accessories and software version before purchase.

Applications for this instrument

See how the model is positioned for real measurement tasks.

Let’s talk about your application

Find the right instrument for your application

Share your sample, measurement requirements and preferred configuration.

Contact our team