W9000 Series
Water Analysis Instrument W9000
A multi-parameter water analysis platform with an 11-inch touchscreen, Bluetooth connection and more than 50 preset methods for bench and field use.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| Wavelength Accuracy | ±0.1nm (at 656.1nm), ±0.3nm full area |
|---|---|
| Photometric Range | -0.3-3A, 0-9999C (0-9999F) |
| Transmittance accuracy | ±0.3% T (0-100% T) ±0.002A (0–0.5A) ±0.003A (0.5A–1A) |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelModel comparison
Water Analysis Instrument W9000 range at a glance
Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.
| Parameter | W9000-X | W9000-D | W9000-W |
|---|---|---|---|
| Wavelength Range | 190-1100 nm | 190-1100 nm | 320-1100 nm |
| Wavelength Accuracy | ±0.1nm (at 656.1nm), ±0.3nm full area | ±0.1nm (at 656.1nm), ±0.3nm full area | ±0.1nm (at 656.1nm), ±0.3nm full area |
| Photometric Range | -0.3-3A, 0-9999C (0-9999F) | -0.3-3A, 0-9999C (0-9999F) | .-0.3-3A, 0-9999C (0-9999F) |
| Transmittance accuracy | ±0.3% T (0-100% T) ±0.002A (0–0.5A) ±0.003A (0.5A–1A) | ±0.3% T (0-100% T) ±0.002A (0–0.5A) ±0.003A (0.5A–1A) | ±0.3% T (0-100% T) ±0.002A (0–0.5A) ±0.003A (0.5A–1A) |
| Transmittance repeatability | 0.15% T (0-100% T) ±0.001A (0–0.5A) ±0.0015A (0.5A–1A) | 0.15% T (0-100% T) ±0.001A (0–0.5A) ±0.0015A (0.5A–1A) | 0.15% T (0-100% T) ±0.001A (0–0.5A) ±0.0015A (0.5A–1A) |
| Baseline Flatness | ±0.0015A | ±0.0015A | ±0.0015A |
| Stray Light | 0.03%T (220nm, 360nm) | 0.03%T (220nm, 360nm) | 0.03%T (220nm, 360nm) |
| Noise | ±0.0002A (after 500nm preheating) | ±0.0002A (after 500nm preheating) | ±0.0002A (after 500nm preheating) |
| Light Source | Xenon Lamp | Deuterium & Tungsten Lamp | Tungsten Lamp |
| Detector | Silicon Photodiode | Silicon Photodiode | Silicon Photodiode |
| Work Mode | T, A, C, E | T, A, C, E | T, A, C, E |
| Output | Cloud connectivity/Email/SMS/Bluetooth/Wi-Fi | Cloud connectivity/Email/SMS/Bluetooth/Wi-Fi | Cloud connectivity/Email/SMS/Bluetooth/Wi-Fi |
| Power | AC 220V/50Hz or AC 110V/60Hz | AC 220V/50Hz or AC 110V/60Hz | AC 220V/50Hz or AC 110V/60Hz |
Shaded labels mark the specifications that differ between models.
Overview
What this instrument measures, and how it fits the range.
The Water Analysis Instrument W9000 covers 3 models, W9000-X to W9000-W. Wavelength range runs from 190 nm to 1100 nm. The comparison table lists every value side by side.
Key points
- Over 50 pre-programmed testing methods.
- Equipped with GLP/GMP functions, including user management, audit tracking, log inquiry, etc.
- Support real-time sending of data via email and mobile SMS.
- Can save various types of data and graphs, can directly export data for editing, measurement and storage.
- Functions include NFC, cloud interconnection, power-off protection, etc.
Full specifications for this model are listed at the top of this page.
Accessories
Confirm these items before the final quotation. Accessories are listed only where the manufacturer offers them.
Standard accessories
Ask for an itemized quotation that separates standard items from options.
Optional accessories
No optional accessories are published for this model. Confirm availability with our team.
Common selection questions
Confirm requirements with our team before the final order.
What does the preset method library cover?
The W9000 ships with more than 50 built-in methods for common water and wastewater parameters, and the platform adds wavelength scanning for anything not in the library. Confirm the specific parameters you report against your local standard before the unit is ordered — method equivalence is a regulatory question, not a hardware one.
Is the W9000 suitable for field sampling?
It is a bench platform with an 11-inch touchscreen, so it stays in the laboratory. The portable multi-parameter analyzer — the MIS1000 with its rechargeable battery and built-in printer — is the field option. Labs that do both usually pair the two: screening on site, confirmation on the bench.
How do results reach our records?
Cloud connectivity, e-mail, SMS, Bluetooth and Wi-Fi are all supported alongside local export. Laboratories that keep paper records print at the bench; those running a LIMS use the network path. Decide which before installation, because the network settings are easiest to agree with IT up front.
Let’s talk about your application
Find the right instrument for your application
Share your sample, measurement requirements and preferred configuration.