FP-D Series Intelligent Flame Photometer

Built-in Oil-Free Air Compressor: No external air compressor required; plug-and-play operation saves laboratory space.

Category Flame Photometer In production
FP-D Series Intelligent Flame Photometer core specifications
Display 7-inch color touchscreen
Display Results Concentration value/Energy
Reading Range 0.000~99999.999/0~65535

Send your sample type and method, and we will confirm the configuration and current lead time.

Ask about this model

[email protected]

Model comparison

FP-D Series Intelligent Flame Photometer range at a glance

Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.

FP-D Series Intelligent Flame Photometer — 7 models
ParameterFP6450DFP6440DFP6432DFP6431DFP6430DFP6410DFP6400D
Display7-inch color touchscreen7-inch color touchscreen7-inch color touchscreen7-inch color touchscreen7-inch color touchscreen7-inch color touchscreen7-inch color touchscreen
Display ResultsConcentration value/EnergyConcentration value/EnergyConcentration value/EnergyConcentration value/EnergyConcentration value/EnergyConcentration value/EnergyConcentration value/Energy
Reading Range0.000~99999.999/0~655350.000~99999.999/0~655350.000~99999.999/0~655350.000~99999.999/0~655350.000~99999.999/0~655350.000~99999.999/0~655350.000~99999.999/0~65535
Measurable elementsK, Na, Li, Ca, BaK, Na, Li, CaK, Na, BaK, Na, CaK, Na, LiK, NaK, Na
Number of channels5433322
Detection limit (ppm)≤0.004; ≤0.008; ≤0.015; ≤0.050; ≤0.044≤0.004; ≤0.008; ≤0.015; ≤0.050; ——≤0.004; ≤0.008; ——; ——; ≤0.044≤0.004; ≤0.008; ——; ≤0.050; ——≤0.004; ≤0.008; ≤0.015; ——; ——≤0.004; ≤0.008; ——; ——; ——≤0.004; ≤0.008; ——; ——; ——
Linear Error≤0.005; ≤0.03; ≤0.021; ≤0.075; ≤0.066≤0.005; ≤0.03; ≤0.021; ≤0.075; ——≤0.005; ≤0.03; ——; ——; ≤0.066≤0.005; ≤0.03; ——; ≤0.075; ——≤0.005; ≤0.03; ≤0.021; ——; ——≤0.005; ≤0.03; ——; ——; ——≤0.005; ≤0.03; ——; ——; ——
Response Time<8S<8S<8S<8S<8S<8S<8S
Sample uptake rate<6ml/min<6ml/min<6ml/min<6ml/min<6ml/min<6ml/min<6ml/min
StabilityContinuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%.
Reproducibility≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples≤3% coefficient of variation for 7 consecutive samples
Bluetooth PrinterYesYesYesYesYesYesNo
OutputUSB portUSB portUSB portUSB portUSB portUSB portUSB port
PowerAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60HzAC 220V/50Hz or AC 110V/60Hz

Overview

What this instrument measures, and how it fits the range.

The FP-D Series Intelligent Flame Photometer covers 7 models, FP6450D to FP6400D. The comparison table lists every value side by side.

Key points

  • Built-in Oil-Free Air Compressor: No external air compressor required; plug-and-play operation saves laboratory space.
  • Gas Leak Alarm System: Real-time monitoring of gas status with automatic alarms in case of abnormalities.
  • Multiple Safety Protections: Automatic ignition, flame-out protection, and gas circuit abnormality alarm.
  • Supports PC software operation, USB storage, printing, and historical data traceability.
  • High-Stability Detection Performance: Fast response, excellent repeatability, and stable long-term operation.

Full specifications for this model are listed at the top of this page.

Accessories

Confirm these items before the final quotation. Accessories are listed only where the manufacturer offers them.

Standard accessories

Ask for an itemized quotation that separates standard items from options.

Optional accessories

No optional accessories are published for this model. Confirm availability with our team.

Specifications can depend on the selected configuration. Confirm the current datasheet, accessories and software version before purchase.

Let’s talk about your application

Find the right instrument for your application

Share your sample, measurement requirements and preferred configuration.

Contact our team