FP-D Series Intelligent Flame Photometer
Built-in Oil-Free Air Compressor: No external air compressor required; plug-and-play operation saves laboratory space.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| Display | 7-inch color touchscreen |
|---|---|
| Display Results | Concentration value/Energy |
| Reading Range | 0.000~99999.999/0~65535 |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelModel comparison
FP-D Series Intelligent Flame Photometer range at a glance
Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.
| Parameter | FP6450D | FP6440D | FP6432D | FP6431D | FP6430D | FP6410D | FP6400D |
|---|---|---|---|---|---|---|---|
| Display | 7-inch color touchscreen | 7-inch color touchscreen | 7-inch color touchscreen | 7-inch color touchscreen | 7-inch color touchscreen | 7-inch color touchscreen | 7-inch color touchscreen |
| Display Results | Concentration value/Energy | Concentration value/Energy | Concentration value/Energy | Concentration value/Energy | Concentration value/Energy | Concentration value/Energy | Concentration value/Energy |
| Reading Range | 0.000~99999.999/0~65535 | 0.000~99999.999/0~65535 | 0.000~99999.999/0~65535 | 0.000~99999.999/0~65535 | 0.000~99999.999/0~65535 | 0.000~99999.999/0~65535 | 0.000~99999.999/0~65535 |
| Measurable elements | K, Na, Li, Ca, Ba | K, Na, Li, Ca | K, Na, Ba | K, Na, Ca | K, Na, Li | K, Na | K, Na |
| Number of channels | 5 | 4 | 3 | 3 | 3 | 2 | 2 |
| Detection limit (ppm) | ≤0.004; ≤0.008; ≤0.015; ≤0.050; ≤0.044 | ≤0.004; ≤0.008; ≤0.015; ≤0.050; —— | ≤0.004; ≤0.008; ——; ——; ≤0.044 | ≤0.004; ≤0.008; ——; ≤0.050; —— | ≤0.004; ≤0.008; ≤0.015; ——; —— | ≤0.004; ≤0.008; ——; ——; —— | ≤0.004; ≤0.008; ——; ——; —— |
| Linear Error | ≤0.005; ≤0.03; ≤0.021; ≤0.075; ≤0.066 | ≤0.005; ≤0.03; ≤0.021; ≤0.075; —— | ≤0.005; ≤0.03; ——; ——; ≤0.066 | ≤0.005; ≤0.03; ——; ≤0.075; —— | ≤0.005; ≤0.03; ≤0.021; ——; —— | ≤0.005; ≤0.03; ——; ——; —— | ≤0.005; ≤0.03; ——; ——; —— |
| Response Time | <8S | <8S | <8S | <8S | <8S | <8S | <8S |
| Sample uptake rate | <6ml/min | <6ml/min | <6ml/min | <6ml/min | <6ml/min | <6ml/min | <6ml/min |
| Stability | Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%. | Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%. | Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%. | Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%. | Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%. | Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%. | Continuous Injection with Standard Solution: The relative maximum change in the instrument reading within 15 s shall be ≤ 3%. Measure once per minute for a total of 6 measurements: the relative maximum change in the instrument reading shall be ≤ 15%. |
| Reproducibility | ≤3% coefficient of variation for 7 consecutive samples | ≤3% coefficient of variation for 7 consecutive samples | ≤3% coefficient of variation for 7 consecutive samples | ≤3% coefficient of variation for 7 consecutive samples | ≤3% coefficient of variation for 7 consecutive samples | ≤3% coefficient of variation for 7 consecutive samples | ≤3% coefficient of variation for 7 consecutive samples |
| Bluetooth Printer | Yes | Yes | Yes | Yes | Yes | Yes | No |
| Output | USB port | USB port | USB port | USB port | USB port | USB port | USB port |
| Power | AC 220V/50Hz or AC 110V/60Hz | AC 220V/50Hz or AC 110V/60Hz | AC 220V/50Hz or AC 110V/60Hz | AC 220V/50Hz or AC 110V/60Hz | AC 220V/50Hz or AC 110V/60Hz | AC 220V/50Hz or AC 110V/60Hz | AC 220V/50Hz or AC 110V/60Hz |
Overview
What this instrument measures, and how it fits the range.
The FP-D Series Intelligent Flame Photometer covers 7 models, FP6450D to FP6400D. The comparison table lists every value side by side.
Key points
- Built-in Oil-Free Air Compressor: No external air compressor required; plug-and-play operation saves laboratory space.
- Gas Leak Alarm System: Real-time monitoring of gas status with automatic alarms in case of abnormalities.
- Multiple Safety Protections: Automatic ignition, flame-out protection, and gas circuit abnormality alarm.
- Supports PC software operation, USB storage, printing, and historical data traceability.
- High-Stability Detection Performance: Fast response, excellent repeatability, and stable long-term operation.
Full specifications for this model are listed at the top of this page.
Accessories
Confirm these items before the final quotation. Accessories are listed only where the manufacturer offers them.
Standard accessories
Ask for an itemized quotation that separates standard items from options.