Explore ApplicationsEpc control range: pressure 0~ 0.6kPa flow 0~500 sccm; Linear range: ≥10⁷.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| Communication | Network communication via an IEEE 802.3 Ethernet interface; the workstation also supports an RS232 communication interface |
|---|---|
| EPC working mode | constant current, constant voltage, split mode |
| EPC working gases | N₂, H₂, Air, He, Ar |
| EPC control range | pressure 0~ 0.6kPa flow 0~500 sccm |
| EPC control accuracy | pressure 0.01kPa; Flow rate of 0.01 sccm |
| Remote monitoring | Real-time monitoring of instrument operation, online/offline status, and operating parameters |
| Instrument control | Remotely adjust instrument parameters and control instrument operations, such as ignition (for gas chromatography), sample injection, and analysis |
| Data acquisition and transmission | Real-time chromatographic data acquired by the instrument can be transmitted to the cloud platform |
| Data storage and analysis | The cloud platform stores transmitted data and allows users to view, analyze, and share chromatograms |
| Number of temperature control channels | 10 |
| Temperature control range | Column oven temperature: Ambient temperature +4 °C to 450°C (1°C increments) |
| Temperature control accuracy/stability | ≤0.1% |
| Display resolution | 0.01°C |
| Temperature programming | 23 steps (expandable to an unlimited number of steps) |
| Temperature ramp rate | 0- 40°C/min (adjustment increments: 0.1°C/min) |
| Maximum heating rate | 80°C/min |
| Temperature programming repeatability | ≤0.5% |
| Cooling time | ≤8 min (from 300°C to 50°C, with automatic door opening) |
| Detection Limit | ≤3 × 10⁻¹² g/s (n-hexadecane) |
| Baseline Noise | ≤5×10⁻¹⁴A |
| Baseline Drift | ≤1×10⁻¹³A/30min |
| Linear range | ≥10⁷ |
| Sensitivity | S≥3000mv.mL/mg |
| Baseline Noise | ≤10µV |
| Baseline Drift | ≤30µV/30min |
| Linear range | ≥10⁵ |
| Carrier gas velocity stability | ≤1% |
| Limit of detection | 5×10⁻¹²g/s(S) (S in methyl parathion) |
| Linear range | 10⁵(P) 10³(S) |
| Maximum operating temperature | 350°C |
| Detection Method | Air-hydrogen flame spectrometry |
| Optical detector | Top photomultiplier |
| Photomultiplier voltage | Max--700V |
| Limit of detection | ≤1×10⁻¹⁴g/s |
| Linear range | 10⁴ |
| Source | Ni⁶³ |
| Limit of detection | (N)≤5×10⁻¹²g/s |
| Power supply | 220 V ± 22 V, 50 Hz ± 0.5 Hz |
| Rated power | <1800 W |
| Ambient temperature | +5°C to +35°C |
| Relative humidity | ≤85% |
| Coal gas and biogas analysis (six components | H₂, O₂, N₂, CH₄, CO, and CO₂), featuring a unique single-valve sequential switching system |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelWhat this instrument measures, and how it fits the range.
GC-7860F is a gas chromatograph with a 4 °C to 450 °C oven, networked instrument control and a detection limit of 1×10⁻¹⁴ g/s.
Full specifications for this model are listed at the top of this page.
Confirm these items before the final quotation. Accessories are listed only where the manufacturer offers them.
Ask for an itemized quotation that separates standard items from options.
Confirm requirements with our team before the final order.
The 7860F adds a 10-inch touchscreen, 23-step temperature programming (expandable) with a 0–40 °C/min ramp, 10 temperature-control channels and a cloud platform for remote monitoring and data storage. Both share the EPC range and the detector options.
It stores transmitted chromatographic data for review, and the same connection lets an operator monitor instrument status and adjust parameters remotely. Agree the data-residency terms with your IT team before it is enabled.
From 300 °C to 50 °C in ≤8 minutes with automatic door opening, which is what shortens the cycle time between programmed temperature runs. Maximum heating rate is 80 °C/min.