Five scanning spectrophotometers from UV1700 to V1710 with 2 nm spectral bandwidth, 0.2 percent T photometric repeatability and plus or minus 0.002 A baseline flatness.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| Optical System | Single Beam, Grating 1200 lines/mm |
|---|---|
| Photometric Repeatability | 0.2%T |
| Photometric Range | 0-200%T, -0.3~3A, 0-9999C |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelModel comparison
1700 Series Scanning Spectrophotometer range at a glance
Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.
| Parameter | UV1700 | UV1710 | UV1720 | V1700 | V1710 |
|---|---|---|---|---|---|
| Optical System | Single Beam, Grating 1200 lines/mm | Single Beam, Grating 1200 lines/mm | Single Beam, Grating 1200 lines/mm | Single Beam, Grating 1200 lines/mm | Single Beam, Grating 1200 lines/mm |
| Wavelength Range | 190-1100nm | 190-1100nm | 190-1100nm | 320-1100nm | 340-1050nm |
| Spectral Bandwidth | 2 nm | 2 nm | 2 nm | 2 nm | 4nm |
| Wavelength Accuracy | ±0.3 nm | ±0.5 nm | 1nm | ±0.5 nm | 1nm |
| Wavelength Repeatability | ≤0.1 nm | ≤0.2 nm | ≤0.2 nm | ≤0.1 nm | ≤0.2 nm |
| Photometric Accuracy | 0.3%T | 0.5%T | 0.5%T | 0.3%T | 0.5%T |
| Photometric Repeatability | 0.2%T | 0.2%T | 0.2%T | 0.2%T | 0.2%T |
| Photometric Range | 0-200%T, -0.3~3A, 0-9999C | 0-200%T, -0.3~3A, 0-9999C | 0-200%T, -0.3~3A, 0-9999C | 0-200%T, -0.3~3A, 0-9999C | 0-200%T, -0.3~3A, 0-9999C |
| Stray light | 0.05%T | 0.1%T | 0.15%T | 0.05%T | 0.15%T |
| Stability | ±0.0001A/h@500nm | ±0.0002A/h@500nm | ±0.0002A/h@500nm | ±0.0001A/h@500nm | ±0.0002A/h@500nm |
| Baseline Flatness | ±0.002 A | ±0.002 A | ±0.002 A | ±0.002 A | ±0.002 A |
| Noise | ±0.001 A | ±0.001 A | ±0.001 A | ±0.001 A | ±0.001 A |
| Work Mode | T, A, C, E | T, A, C, E | T, A, C, E | T, A, C, E | T, A, C, E |
| Wavelength Setting | Auto | Auto | Auto | Auto | Auto |
| Display | 128*64 LCD | 128*64 LCD | 128*64 LCD | 128*64 LCD | 128*64 LCD |
| Light Source | Deuterium & Tungsten lamp | Deuterium & Tungsten lamp | Deuterium & Tungsten lamp | Tungsten lamp | Tungsten lamp |
| Detector | Silicon Photodiode | Silicon Photodiode | Silicon Photodiode | Silicon Photodiode | Silicon Photodiode |
| Cuvette Holder | 10mm manual 4-cell holder | 10mm manual 4-cell holder | 10mm manual 4-cell holder | 10mm manual 4-cell holder | 10mm manual 4-cell holder |
| Output | USB, RS232 | USB, RS232 | USB, RS232 | USB, RS232 | USB, RS232 |
| Power | AC 110-220V 50-60Hz | AC 110-220V 50-60Hz | AC 110-220V 50-60Hz | AC 110-220V 50-60Hz | AC 110-220V 50-60Hz |
Overview
What this instrument measures, and how it fits the range.
The 1700 Series Scanning Spectrophotometer covers 5 models, UV1700 to V1710. Wavelength range runs from 190 nm to 1100 nm, and spectral bandwidth runs from 2 nm to 4 nm. The comparison table lists every value side by side.
Key points
- The instrument has basic functions of photometric analysis and quantitative analysis.
- Adopts 51 microcomputer system, and can store 200 test data and 100 standard curves.
- Socket-type deuterium and tungsten lamps support lamp switching without optical realignment, and the lamps are easy to replace.
- The large sample compartment accommodates cuvettes with path lengths from 5 to 100 mm.
- Extensive accessories are optional, such as 50/100mm manual 4-cell holder, auto 8-cell holder, film holder, 21 CFR compliant software, etc.
Full specifications for this model are listed at the top of this page.
Accessories
Confirm these items before the final quotation. Accessories are listed only where the manufacturer offers them.
Standard accessories
- 10mm glass cuvette x 4
- 10mm quartz cuvette x 2 (UV)
- Power cord
- User manual
- PC software (UV)
Optional accessories
- 50/100mm manual 4-cell holder
- auto 8-cell holder
- film holder
- 21 CFR compliant software
- PC software
Product documentation
- Brochure Yoke product guide Download
- Selection guide Prepare a UV-Vis purchase brief v1.0 Learn more
Let’s talk about your application
Find the right instrument for your application
Share your sample, measurement requirements and preferred configuration.