1900 Series Double Beam Spectrophotometer

Three double-beam spectrophotometers from UV1900 to UV1901S covering 190-1100 nm with 0.1 nm wavelength repeatability and 0.2 percent T photometric accuracy.

Category UV-Vis Spectrophotometer In production
1900 Series Double Beam Spectrophotometer core specifications
Optical System Double Beam, Grating 1200 lines/mm
Wavelength Range 190-1100 nm
Wavelength Accuracy ±0.1 nm @ 656.1 nm, ±0.3 nm @ all

Send your sample type and method, and we will confirm the configuration and current lead time.

Ask about this model

[email protected]

Model comparison

1900 Series Double Beam Spectrophotometer range at a glance

Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.

1900 Series Double Beam Spectrophotometer — 3 models
ParameterUV1900UV1901UV1901S
Optical SystemDouble Beam, Grating 1200 lines/mmDouble Beam, Grating 1200 lines/mmDouble Beam, Grating 1200 lines/mm
Wavelength Range190-1100 nm190-1100 nm190-1100 nm
Spectral Bandwidth2nm1nm0.5/1/2/4/5nm
Wavelength Accuracy±0.1 nm @ 656.1 nm, ±0.3 nm @ all±0.1 nm @ 656.1 nm, ±0.3 nm @ all±0.1 nm @ 656.1 nm, ±0.3 nm @ all
Wavelength Repeatability≤0.1nm≤0.1nm≤0.1nm
Photometric Accuracy0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)
Photometric Repeatability≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)
Photometric Range0-200%T, -0.3~3A, 0-9999C0-200%T, -0.3~3A, 0-9999C0-200%T, -0.3~3A, 0-9999C
Stray Light≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm
Stability±0.0005A/h@500nm±0.0005A/h@500nm±0.0005A/h@500nm
Baseline Flatness±0.002A±0.001A±0.001A
Noise0.0005A@500nm0.0005A@500nm0.0005A@500nm
Work ModeT, A, C, ET, A, C, ET, A, C, E
Scanning SpeedHi, Med, Low (Max. 3000nm/min)Hi, Med, Low (Max. 3000nm/min)Hi, Med, Low (Max. 3000nm/min)
Wavelength SettingAutoAutoAuto
Display320*240 LCD320*240 LCD320*240 LCD
Light SourceDeuterium & Tungsten lampDeuterium & Tungsten lampDeuterium & Tungsten lamp
DetectorSilicon PhotodiodeSilicon PhotodiodeSilicon Photodiode
Cuvette Holder10mm manual 4-cell holder10mm manual 4-cell holder10mm manual 4-cell holder
OutputUSB, RS232USB, RS232USB, RS232
PowerAC 110-220V 50-60HzAC 110-220V 50-60HzAC 110-220V 50-60Hz

Shaded labels mark the specifications that differ between models.

Overview

What this instrument measures, and how it fits the range.

The 1900 Series Double Beam Spectrophotometer covers 3 models, UV1900 to UV1901S. Spectral bandwidth differs across models: 2nm, 1nm or 0.5/1/2/4/5nm. The comparison table lists every value side by side.

Key points

  • Large 320*240 dots highlighted LCD.
  • Functions include photometric measurement, quantitative analysis, kinetics, wavelength scanning, DNA/protein analysis and multi-wavelength measurement.
  • In-house massive memory is capable of saving up to 1024M for test data & working curves.
  • Supports USB storage. The USB port can be used for data transfer and exporting to Excel for further processing, analysis and storage.
  • Socket-type deuterium and tungsten lamps support lamp switching without optical realignment, and the lamps are easy to replace.
  • The large sample compartment accommodates cuvettes with path lengths from 5 to 100 mm.
  • Extensive accessories are optional, such as auto 8-cell holder, film holder, tube rack, Peltier temperature-control / sipper system, integrating sphere, reflection accessory, 21 CFR compliant software, etc.

Full specifications for this model are listed at the top of this page.

Accessories

Confirm these items before the final quotation. Accessories are listed only where the manufacturer offers them.

Standard accessories

  • 10mm glass cuvette x 4
  • 10mm quartz cuvette x 2
  • Power cord
  • User manual
  • PC software

Optional accessories

  • auto 8-cell holder
  • film holder
  • tube rack
  • Peltier temperature-control / sipper system
  • integrating sphere
  • reflection accessory
  • 21 CFR compliant software
Specifications can depend on the selected configuration. Confirm the current datasheet, accessories and software version before purchase.