Pharmaceuticals & Biotechnology
Analytical testing and pharmaceutical laboratory research.
Explore ApplicationsThree double-beam spectrophotometers from UV1900 to UV1901S covering 190-1100 nm with 0.1 nm wavelength repeatability and 0.2 percent T photometric accuracy.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| Optical System | Double Beam, Grating 1200 lines/mm |
|---|---|
| Wavelength Range | 190-1100 nm |
| Wavelength Accuracy | ±0.1 nm @ 656.1 nm, ±0.3 nm @ all |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelModel comparison
Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.
| Parameter | UV1900 | UV1901 | UV1901S |
|---|---|---|---|
| Optical System | Double Beam, Grating 1200 lines/mm | Double Beam, Grating 1200 lines/mm | Double Beam, Grating 1200 lines/mm |
| Wavelength Range | 190-1100 nm | 190-1100 nm | 190-1100 nm |
| Spectral Bandwidth | 2nm | 1nm | 0.5/1/2/4/5nm |
| Wavelength Accuracy | ±0.1 nm @ 656.1 nm, ±0.3 nm @ all | ±0.1 nm @ 656.1 nm, ±0.3 nm @ all | ±0.1 nm @ 656.1 nm, ±0.3 nm @ all |
| Wavelength Repeatability | ≤0.1nm | ≤0.1nm | ≤0.1nm |
| Photometric Accuracy | 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A) | 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A) | 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A) |
| Photometric Repeatability | ≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) | ≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) | ≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A) |
| Photometric Range | 0-200%T, -0.3~3A, 0-9999C | 0-200%T, -0.3~3A, 0-9999C | 0-200%T, -0.3~3A, 0-9999C |
| Stray Light | ≤0.03%T@220nm, 360nm | ≤0.03%T@220nm, 360nm | ≤0.03%T@220nm, 360nm |
| Stability | ±0.0005A/h@500nm | ±0.0005A/h@500nm | ±0.0005A/h@500nm |
| Baseline Flatness | ±0.002A | ±0.001A | ±0.001A |
| Noise | 0.0005A@500nm | 0.0005A@500nm | 0.0005A@500nm |
| Work Mode | T, A, C, E | T, A, C, E | T, A, C, E |
| Scanning Speed | Hi, Med, Low (Max. 3000nm/min) | Hi, Med, Low (Max. 3000nm/min) | Hi, Med, Low (Max. 3000nm/min) |
| Wavelength Setting | Auto | Auto | Auto |
| Display | 320*240 LCD | 320*240 LCD | 320*240 LCD |
| Light Source | Deuterium & Tungsten lamp | Deuterium & Tungsten lamp | Deuterium & Tungsten lamp |
| Detector | Silicon Photodiode | Silicon Photodiode | Silicon Photodiode |
| Cuvette Holder | 10mm manual 4-cell holder | 10mm manual 4-cell holder | 10mm manual 4-cell holder |
| Output | USB, RS232 | USB, RS232 | USB, RS232 |
| Power | AC 110-220V 50-60Hz | AC 110-220V 50-60Hz | AC 110-220V 50-60Hz |
Shaded labels mark the specifications that differ between models.
What this instrument measures, and how it fits the range.
The 1900 Series Double Beam Spectrophotometer covers 3 models, UV1900 to UV1901S. Spectral bandwidth differs across models: 2nm, 1nm or 0.5/1/2/4/5nm. The comparison table lists every value side by side.
Full specifications for this model are listed at the top of this page.
Confirm these items before the final quotation. Accessories are listed only where the manufacturer offers them.
See how the model is positioned for real measurement tasks.
Analytical testing and pharmaceutical laboratory research.
Explore ApplicationsChemical testing and material quality control.
Explore ApplicationsLet’s talk about your application
Share your sample, measurement requirements and preferred configuration.