K Series Touch Screen Spectrophotometer

Wavelength range: 190-1100 nm; Photometric range: 0-200%T, -0.3~3A, 0-9999C.

Category UV-Vis Spectrophotometer In production
K Series Touch Screen Spectrophotometer core specifications
Wavelength Range 190-1100 nm
Wavelength Accuracy ±0.1 nm @ 656.1 nm, ±0.3 nm @ all
Wavelength Repeatability ≤0.1nm

Send your sample type and method, and we will confirm the configuration and current lead time.

Ask about this model

[email protected]

Model comparison

K Series Touch Screen Spectrophotometer range at a glance

Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.

K Series Touch Screen Spectrophotometer — 6 models
ParameterK7000K7001K7001SK9000K9001K9001S
Optical SystemSingle Beam, Grating 1200 lines/mmSingle Beam, Grating 1200 lines/mmSingle Beam, Grating 1200 lines/mmDouble Beam, Grating 1200 lines/mmDouble Beam, Grating 1200 lines/mmDouble Beam, Grating 1200 lines/mm
Wavelength Range190-1100 nm190-1100 nm190-1100 nm190-1100 nm190-1100 nm190-1100 nm
Spectral Bandwidth2nm1nm0.5/1/2/4/5nm2nm1nm0.5/1/2/4/5nm
Wavelength Accuracy±0.1 nm @ 656.1 nm, ±0.3 nm @ all±0.1 nm @ 656.1 nm, ±0.3 nm @ all±0.1 nm @ 656.1 nm, ±0.3 nm @ all±0.1 nm @ 656.1 nm, ±0.3 nm @ all±0.1 nm @ 656.1 nm, ±0.3 nm @ all±0.1 nm @ 656.1 nm, ±0.3 nm @ all
Wavelength Repeatability≤0.1nm≤0.1nm≤0.1nm≤0.1nm≤0.1nm≤0.1nm
Photometric Accuracy0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)
Photometric Repeatability≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)
Photometric Range0-200%T, -0.3~3A, 0-9999C0-200%T, -0.3~3A, 0-9999C0-200%T, -0.3~3A, 0-9999C0-200%T, -0.3~3A, 0-9999C0-200%T, -0.3~3A, 0-9999C0-200%T, -0.3~3A, 0-9999C
Stray Light≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm≤0.03%T@220nm, 360nm
Stability±0.0005A/h@500nm±0.0005A/h@500nm±0.0005A/h@500nm±0.0003A/h@500nm±0.0003A/h@500nm±0.0003A/h@500nm
Baseline Flatness±0.002A±0.001A±0.001A±0.002A±0.001A±0.001A
Noise0.0005A@500nm0.0005A@500nm0.0005A@500nm0.0005A@500nm0.0005A@500nm0.0005A@500nm
Work ModeT, A, C, ET, A, C, ET, A, C, ET, A, C, ET, A, C, ET, A, C, E
Scanning SpeedHi, Med, Low (Max. 3000nm/min)Hi, Med, Low (Max. 3000nm/min)Hi, Med, Low (Max. 3000nm/min)Hi, Med, Low (Max. 3000nm/min)Hi, Med, Low (Max. 3000nm/min)Hi, Med, Low (Max. 3000nm/min)
Wavelength SettingAutoAutoAutoAutoAutoAuto
Display10.1-inch Touch Screen10.1-inch Touch Screen10.1-inch Touch Screen10.1-inch Touch Screen10.1-inch Touch Screen10.1-inch Touch Screen
Light SourceDeuterium & Tungsten lampDeuterium & Tungsten lampDeuterium & Tungsten lampDeuterium & Tungsten lampDeuterium & Tungsten lampDeuterium & Tungsten lamp
DetectorSilicon PhotodiodeSilicon PhotodiodeSilicon PhotodiodeSilicon PhotodiodeSilicon PhotodiodeSilicon Photodiode
Cuvette Holder10mm manual 4-cell holder10mm manual 4-cell holder10mm manual 4-cell holder10mm single hole cell holder10mm single hole cell holder10mm single hole cell holder
OutputUSB drive, USB host, RS232USB drive, USB host, RS232USB drive, USB host, RS232USB drive, USB host, RS232USB drive, USB host, RS232USB drive, USB host, RS232
PowerAC 110-220V 50-60HzAC 110-220V 50-60HzAC 110-220V 50-60HzAC 110-220V 50-60HzAC 110-220V 50-60HzAC 110-220V 50-60Hz

Shaded labels mark the specifications that differ between models.

Overview

What this instrument measures, and how it fits the range.

The K Series Touch Screen Spectrophotometer covers 6 models, K7000 to K9001S. Spectral bandwidth differs across models: 2nm, 1nm or 0.5/1/2/4/5nm. The comparison table lists every value side by side.

Key points

  • Functions include photometric measurement, quantitative analysis, kinetics, wavelength scanning, DNA/protein analysis and multi-wavelength measurement.
  • In-house massive memory is capable of saving up to 1024M for test data & working curves.
  • Supports USB storage.
  • Socket-type deuterium and tungsten lamps support lamp switching without optical realignment, and the lamps are easy to replace.
  • The large sample compartment accommodates cuvettes with path lengths from 5 to 100 mm.

Full specifications for this model are listed at the top of this page.

Accessories

Confirm these items before the final quotation. Accessories are listed only where the manufacturer offers them.

Standard accessories

  • 10mm glass cuvette x 4
  • 10mm quartz cuvette x 2
  • Power cord
  • User manual
  • PC software

Optional accessories

  • auto 8-cell holder
  • film holder
  • tube rack
  • Peltier temperature-control / sipper system
  • integrating sphere
  • reflection accessory
  • built-in printer
  • 21 CFR compliant software
Specifications can depend on the selected configuration. Confirm the current datasheet, accessories and software version before purchase.