F Series
Fluorescence Spectrophotometer F968/F980
The interface uses a modular layout with clearly labeled function icons.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| Light Source | High-intensity ozone-removing xenon lamp |
|---|---|
| Optical System | C-T double monochromator grating |
| Fluorescence Detector | Original Hamamatsu photomultiplier tube (PMT) |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelModel comparison
Fluorescence Spectrophotometer F968/F980 range at a glance
Full specifications for every model in the series, side by side. Tell us the sample type and throughput you need and we will point to the closest configuration.
| Parameter | F968 | F980 |
|---|---|---|
| Light Source | High-intensity ozone-removing xenon lamp | High-intensity ozone-removing xenon lamp |
| Optical System | C-T double monochromator grating | C-T double monochromator grating |
| Fluorescence Detector | Original Hamamatsu photomultiplier tube (PMT) | Original Hamamatsu photomultiplier tube (PMT) |
| Excitation Wavelength Range | 200–900 nm | 200–900 nm |
| Excitation/ Emission Bandwidth | 10nm | 1nm/2nm/5nm/10nm/20nm |
| Emission Wavelength Range | 200-900nm | 200-900nm |
| Emission Wavelength Accuracy | ±1.0nm | ±0.4nm |
| Emission Wavelength Repeatability | ≤0.5nm | ≤0.2nm |
| Wavelength Scanning Speed | 5 speeds: Ultra-fast, Fast, Medium, Slow, Ultra-slow | 5 speeds: Ultra-fast, Fast, Medium, Slow, Ultra-slow |
| Detection Sensitivity (SNR) | S/N ≥90 (P-P) | S/N ≥90 (P-P) |
| Peak Intensity Repeatability | ≤1.5% | ≤1.5% |
| Measurement Linearity | Correlation coefficient ≥ 0.995 | Correlation coefficient ≥ 0.995 |
| Data Transmission Mode | RS232 serial port, USB-B, USB-A | RS232 serial port, USB-B, USB-A |
| PC Software | Optional (optional 21 CFR compliant software) | Optional (optional 21 CFR compliant software) |
| Power | 220V/50HZ | 220V/50HZ |
Shaded labels mark the specifications that differ between models.
Overview
What this instrument measures, and how it fits the range.
The Fluorescence Spectrophotometer F968/F980 covers 2 models, F968 to F980. Emission wavelength accuracy runs from ±0.4 nm to ±1 nm. The comparison table lists every value side by side.
Key points
- Both excitation and emission spectra cover a continuous range from 200 nm to 900 nm, accommodating most fluorescence analysis applications.
- Overlay spectra to compare standards, samples or batches. Spectrum subtraction and ratio calculations are also available.
- The bundled software supports multiple advanced modes including 3D fluorescence scanning, constant wavelength difference synchronous scanning and constant wavenumber difference synchronous scanning.
- The bundled software is embedded with limit of detection (LOD) test function, which automatically completes sensitivity verification for low-concentration samples and quickly determines the method’s…
- The audit trail function of the matching PC software automatically records full-process immutable data, fully complying with regulatory requirements including FDA 21 CFR Part 11 and PIC/S GMP.
Full specifications for this model are listed at the top of this page.
Accessories
Confirm these items before the final quotation. Accessories are listed only where the manufacturer offers them.
Standard accessories
Ask for an itemized quotation that separates standard items from options.
Optional accessories
- PC software
- 21 CFR compliant software
Let’s talk about your application
Find the right instrument for your application
Share your sample, measurement requirements and preferred configuration.