F Series
F960 Fluorescence Spectrophotometer
11-inch touchscreen with an ergonomic control panel, operable by touch or stylus.
Documentation
Datasheets and manuals are issued per model and revision. Ask for the documents that match the configuration you are considering.
See linked documents| Light Source | High-intensity ozone-removing xenon lamp |
|---|---|
| Optical System | C-T single monochromator grating |
| Fluorescence Detector | Original Hamamatsu photomultiplier tube (PMT) |
| Excitation Wavelength Range | 250–850nm (Filter) |
| Excitation Bandwidth | 10nm |
| Emission Wavelength Range | 200-900nm |
| Emission Bandwidth | 10nm |
| Emission Wavelength Accuracy | ±1.0 nm |
| Emission Wavelength Repeatability | ≤0.5 nm |
| Wavelength Scanning Speed | 5 speeds: Ultra-fast, Fast, Medium, Slow, Ultra-slow |
| Detection Sensitivity (SNR) | S/N ≥90 (P-P) |
| Peak Intensity Repeatability | ≤1.5% |
| Measurement Linearity | Correlation coefficient ≥ 0.995 |
| Data Transmission Mode | RS232 serial port, USB-B, USB-A |
| PC Software | Optional (optional 21 CFR compliant software) |
| Power | 220V/50HZ |
Send your sample type and method, and we will confirm the configuration and current lead time.
Ask about this modelOverview
What this instrument measures, and how it fits the range.
F960 is a fluorescence spectrophotometer in the F Series, with an excitation wavelength range of 250–850 nm and an emission wavelength accuracy of ±1.0 nm.
Key points
- The emission monochromator supports automatic wavelength scanning.
- The excitation side adopts a filter-based optical structure featuring high stability and reliability without calibration requirement, equipped with a light-blocking shutter to shorten sample exposure…
- Multiple spectra can be overlaid for comparison between standards and samples as well as difference analysis of batches, spectrum subtraction and ratio calculation are available.
- The audit trail function of the matching PC software automatically records full-process immutable data, fully complying with regulatory requirements including FDA 21 CFR Part 11 and PIC/S GMP.
Full specifications for this model are listed at the top of this page.
Accessories
Confirm these items before the final quotation. Accessories are listed only where the manufacturer offers them.
Standard accessories
Ask for an itemized quotation that separates standard items from options.
Optional accessories
- PC software
- 21 CFR compliant software